• 福禄克旗下其他公司:
  • Fluke
  • Fluke Biomedical
  • Fluke Networks
  • Fluke Process Instruments
查看更多福禄克品牌
Accelix Amprobe Beha-Amprobe Comark Emaint Landauer Pacific Laser Systems Pomona RaySafe Schad
主页
Precision, Performance, Confidence.
美国福禄克(FLUKE) – 计量校准
  • 注册
  • 登录
  • Contact Us

CN - Chinese, Simplified (简体中文) [Change]

 

PG7000 Ver 2.07h Embedded Software

TITLE VER USE WITH
PG7000™ 2.07h All PG7000 Series models
Instructions:
-Ver 2.02x and 2.03x Users
You can upgrade directly to this version with no special considerations.

-Ver 2.01x Users
Ver 2.02 is a major revision which should be accompanied by hardware changes.

-Ver 1.0x Users
Ver 2.01 is a major revision which should be accompanied by hardware changes. Contact a Fluke Calibration Authorized Service Center for additional information.

Download the file. Run Winflash and select the file downloaded as the file to write to the product.

Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge.

If your product has an model number ending in "-AF", it requires specific "-AF" embedded software.

The updating of embedded software should only be performed after given specific instructions to do so from a Fluke Calibration Authorized Service Center.

If the update isn't performed properly, your product will be inoperable until it is.

Updates Include:
Ver 2.07h (2011 Jan 17)
FIX (PG-486): The PPCH can take a very long time to re-float a piston. In some cases a re-float can never achieve a ready condition. The float algorithm was improved to dramatically reduce the re-float time.

Ver 2.07g (2008 Mar 05)
ADD: Include PPC4 in the list of controllers for automate pressure control.
ADD: Provide a new remote command that returns the pressure from the PG7000's pressure controller when AutoGen automated pressure control is on.
CHG: Change upper limit of bell and piston mass to 2 kg.
FIX: After initialization, PG7601 may assume the bell is not loaded (display ---- and ?? for piston position indication and rotation), when actual mass loaded is in range for bell to be loaded.
FIX: Upgrade of PG7607 from version lower than 2.05 would cause motorized rotation to function improperly.
FIX: Pressure Adder coefficient for vacuum gauge will not display full value if Adder is negative and 2 digits.
FIX: Mass rotation deceleration abort error message trigger is too sensitive.
FIX: Low mass loads accelerate masses very slowly when equiped with solenoid engagement.

Ver 2.07f
Internal mfg only.

Ver 2.07e (2006 Nov 06)
ADD: New remote command "AMHMS" to directly manipulate AMH masses through the PG.
CHG: When floating a 5MPa/kg piston with a PPCH, the control can stall out causing very long
control times, >9min.
CHG: Disable autorotation when a pressure is aborted (ABORT or ) and resume (enable) when the next pressure is entered (PS or ).
CHG: Execute a pressure set of 0 after initialization on power up.
FIX: When the same pressure is requested locally, and rotation predeceleration is on, the masses fully decelerate.
FIX: PGEN=# command fails when issued after a series of remote commands.
FIX: The display can get stuck with the word "Accelerating" or "Decelerating" on the front panel display.
FIX: Using the Mass=1 command then switching from local to remote caused the PG Terminal and
communications to lock up.
FIX: "MASS=" command return error even though correct mass set got set when setting an AMH mass set.
FIX: PG7000 may accelerate rotation prematurely when changing masses.

Ver 2.07d (2006 Jul 17)
ADD: Include rate of change of piston position in the calculation of control abort when floating with PPCH and PG7302.
ADD: Add the ability to specify external volume in PG7302 and PG7307 for use with PPCH and automated
pressure control.
ADD: The calibration report number for piston-cylinders, mass bells, and mass sets needs to support a nine digit entry, yet still support the older five digit ID.
ADD: Floating with PPCH - add a delay if the ready limit is overshot when floating.
CHG: Update values of PPCH float coefficients to improve robustness and performance into volumes.
CHG: Inconsistent mass set mass resolution for commands, responses and PG7000 Terminal display.
FIX: Rotation may not spin up enough with pure gas piston-cylinders.
FIX: [P-C] menu sometimes displays/highlights an inactive piston-cylinder.
FIX: In [SYSTEM}, vacuum rate is <****>, regardless of rate.
FIX: A remotely created piston-cylinder does not display as active when selected with the PG7000 terminal.
FIX: PPC initialization with PPC1 fails in gauge mode.
FIX: PG7000 in diff mode offsets its pressure after being set to gauge mode then back to diff mode REMOTELY. Front panel setup and use is correct.
FIX: The PistonVar command kills the last edit date created by the Piston# command.
FIX: Allow use of a PPC3 for AutoGen while in an altitude unit.
FIX: When feet or meters is the selected unit of measure, the piston-cylinder pressure range needs to be in psi or kPa, respectively when pressing [P-C] on the PG7000 Terminal.
FIX: Where the use of altitude units does not make sense, use psi and kPa for feet and meters, respectively.
FIX: AutoGen by PPCH may end up going in the wrong direction.
FIX: AutoGen with PPCH - abort if large overshoot of target pressure.

Ver 2.07c
Internal mfg only.

Ver 2.07b (2006 Mar 31)
ADD: In automated pressure generation with PPCH, rehomes valves on each control abort.
ADD: Decelerate masses prior to lifting AMH during initialization.
ADD: Ability to delete active piston-cylinder, mass set or mass bell.
ADD: Ability to delete piston-cylinders, bells and mass sets by remote commands.
ADD: Ability to use remote PS command for PG7000 when pressure unit of measure is ft or m.
ADD: Automated pressure generation for PG7202 using PPCH-G pressure controller.
ADD: "load all" remote command for PG7000 with AMH.
ADD: Support new style motorized rotation hardware (eliminates solenoid).
ADD: Remote status code for rotation engaged ('A' for accelerating) to the "PR" and "RS" commands.
ADD: Entry of "0" in mass to pressure mode vents the controller when automated pressure generation is active, like pressure to mass mode.
ADD: Support for to display the mass to pressure conversion coefficient in psi when the nominal conversion coefficient is in psi.
CHG: Improve the stability of the equilibrium fall rate display in high line differential pressure mode.
CHG: PG7202 piston position no longer flashes when ready during automated pressure generation
with PPCH-G.
FIX : AMH discreet mass control main mass entry screen format error.
FIX: In automated pressure generation with PPCH, abort and restart excursion if pressure is going the wrong direction.
FIX: Motorized rotation motor engagement is no longer tripped when AMH masses are lifted.
FIX: In high line differential pressure mode, tare mass is now limited to full scale of the tare PG7000 mass set.
FIX: RESUME=0 is default state, not requiring RESUME command to start autogeneration.
FIX: In high line differential pressure mode, motorized rotation engagement sequences corrected.
FIX: Update default piston rotation Ready limits.
FIX: Correct error in very low absolute pressure automated pressure generation.
FIX: MS=0 executes a vent when automated pressure generation is enabled.
FIX: Masses are decelerated prior to vent if automated pressure generation is ON.
FIX: Automated pressure generation from vent would sometimes not generate pressure with a new pressure set.
FIX: With automated pressure generation ON, new targets sent to PG7000 do not always result in target sent (and accepted) in PPCH.
FIX: [P-C] screen does not allow enough characters for a 100+ MPa range when unit of measure is kPa.
FIX: PG7302 high line differential option to be always enabled.
FIX: When using automated pressure generation with a PG7302, selecting a new piston-cylinder to update PPCH settings automatically.
FIX: In high line differential mode, if a mass is used to achieve a target line pressure, it should no longer be available for differential pressure.

Ver 2.07 - 2.07a (2006 Mar 15)
Internal mfg only.

Ver 2.06c (2005 Nov 28)
ADD: pressure units "Torr" and "mTor"
ADD: When using AutoGen with PPCH, do not refloat the piston if the piston position is between the float target and the upper ready limit. This avoids needless pressure regeneration when making small mass load changes.
ADD: New option in the [AutoGen] menu to skip having the automated pressure controller (PPC) readjust piston position to the target position when a new pressure command is given and the piston is already anywhere within the piston position "Ready" limits.
ADD: Improved PPCH low pressure control. Avoids excessive overshoots on low pressure (100 to 500 kPa/kg) piston-cylinders.
ADD: In the response to the "PR" command, list a "V" in the 3rd character space (after "R " or "NR") to indicate that the vacuum reference is "Not Ready".
ADD: Support for external vacuum sensor isolation valve controlled by a valve driver on the PPC3 use for automated pressure generation. Actuation of the isolation valve occurs automatically if an external vacuum sensor is active in the current SETUP.
CHG: Default low piston rotation limit in piston-cylinder file to 10 RPM rather than 20 on gas operated piston-cylinders (PG7102, PG7601, PG7607
FIX: PG7000 may stop communications with an AMH when an external barometer or vacuum sensor is not being used.

Ver 2.06b (2005 Nov 01)
FIX: Torr and mTorr unit conversions.

Ver 2.06a (2005 May 19)
FIX: In PG7302, AutoGen with PPCH may control pressure in wrong direction in certain situations when floating or refloating the piston.
FIX: Upgrades from version 2.05h and earlier will leave AutoGen by PPCH operation inoperable.
FIX: "NONE" selection was missing from the [SPECIAL], <2presU>, <2other> menu.
FIX: PG did not report a Ready condition when vented with a PPC3 AutoGen active and an external vacuum sensor.

Ver 2.06 (2005 Feb 22)
FIX: Sending "MMODE=G" command to result in normal gauge mode operation.
FIX: With AutoRotate ON, after a PG Terminal initiated deceleration of piston rolation, AutoRotate will not rerotate the piston until a new pressure or mass request is entered. This avoids having the piston rerotate immediately after deceleration if the piston is floating.
FIX: Remote definition of AMH mass sets so that subsequent mass loads are made correctly.

Ver 2.05h (2004 Oct 29)
CHG: Change the user "PRTAMB" command to a factory only.
FIX: Add piston rotation deceleration routine to AutoRotate in differential mode.
FIX: MINMAX command to contain a 3rd return parameter that is the pressure resulting from floating the piston only.
FIX: High line differential mode screens.
FIX: Forced rotation would attempt even if currently rotating and meeting other force rotation criteria.
FIX: Forced rotation should "give up" after three attempts.
FIX: New offset determined from an external barometer while in differential mode incorrectly read from the barometer resulting in a mass load error.
FIX: Allow selection via a menu to select old style LF-CR or normal CR-LF as the transmit termination for COM2 & COM3.
FIX: RPM4 would be improperly set to gauge mode when used as an external barometer.

Ver 2.05g (2004 Sep 28)
FIX: PG7302 could not initialize PPCH as AutoGen pressure controller.

Ver 2.05f (2004 Aug 23)
ADD: When using AutoGen with PPCH, set upper limit (UL) to 10% above the maximum PG7302 pressure to prevent PPCH from grossly exceeding the target when autofloating using rate mode.
ADD: RESUME=0 / RESUME=1 remote commands to not require / require the use of the RESUME command to complete remote pressure setting sequences.
CHG: New method for use of a PPC2+ or PPC3 with AutoGen when floating the piston in the "spring zone".

Ver 2.05e (2004 Jun 28)
ADD: Support for use of an RPM4 as an external barometer.
ADD: When automated pressure generation is on, when floating, piston position must be out of the ready band for three consecutive measurements. This avoids premature refloating.
CHG: When using automated pressure generation with PPCH and with "raise piston before mass handling" on, increase (by 2x) the rate used to raise the piston before mass handling and the rate used to detect if the piston is not progressing.
CHG: Do not alter the state of the control reference (VAC/ATM) on an external PPC2+ or PPC3.
CHG: When using automated pressure generation and with "raise piston before mass handling" on, change limit to raise piston to before mass handling to 2.5 mm.
CHG: resolution reported by the "MASSSETx" command is now 0.1mg for masses 500g and less, 1mg for masses greater than 500g but less than 10kg and 10mg for 10kg and up
FIX: With automated rotation on, forced rotation routine would not hand control off to the normal auto rotation control in some conditions and would continue to attempt forced rotation regardless of rotation speed.

Ver 2.05d (2004 Jun 01)
ADD: Support of PPCH as a pressure controller for AutoGen.
CHG: Forced rotation uses standard acceleration control instead of full power.
FIX: After a reset SETS or reset ALL, set active mass set and piston/cyclinder to the first valid one instead of the first one to prevent activating a previously deleted item

Ver 2.05c (2004 May 07)
ADD: Support for AMH-38 and AMH-100 automated mass handling systems.
ADD: Piston rotation deceleration function to stop piston rotation before changing pressure or manipulating masses (activation of this feature requires re-creating piston-cylinder files).
FIX: Internal real time clock could not properly set the date past year 2009
FIX: "MMODE" correctly accepts the "AATM" argument FIX: Auto generation does not stop floating piston when it crosses the midfloat position but floats piston at target position.
FIX: "PRTAMB" command and "PRTPC" command functions were swapped.
FIX: Piston position would occasionally falsely indicate '0.0' during remote use.
FIX: Longer timeout and retry for communications with extern PPC

Ver 2.05 - 2.05b
Internal mfg only.

Ver 2.04b (2003 Aug 04)
FIX: Recognize presence of motorized rotation system in PG7102, PG7202, PG7302 when upgrade path is not from most recent previous version.

Ver 2.04a(2003 Jun 23)
FIX: Display "*****" in numeric data fields which have overflowed (exceeded their width).
FIX: Modify the make up mass view screen to allow the "kg" text to be fully visible following the make up mass value.
FIX: Fatal Exception would sometimes occur when initializing an external RPM1.
FIX: Update the screen when head, unit or measurement mode is changed remotely.
FIX: '#' command now passes data onto COM2 without adding any additional addressing information.
FIX: Use correct piston file default rotation speed ready criteria for the PG7307.

Ver 2.04 (2002 Jun 11)
ADD: Support for new PG7202.
ADD: Gas density calculations up to 100 MPa for head corrections.
ADD: Platform model based maximum pressure limits.
ADD: Allow PG7302 and PG7202 to be used in high line differential modes.
ADD: Allow use of PG7302 module in PG7202 platform.
FIX: External barometer configuration could become corrupt if an RPM1 is used, and COM2 settings do not match the RPM1's setting.

Ver 2.03 Rev f (2002 Apr 18)
ADD: Support for PG7307
FIX: The "DUTHEIGHT=" remote command setting would be ignored if the DUT height was locally set to '0'.

Ver 2.03 Rev e (2001 May 22)
FIX: Remote command "PGEN" would not return the correct error if an external PPC was not detected.

Ver 2.03 Rev d (2001 Feb 26)
ADD: Support of PG7102 high line differential mode operation.
ADD: 0.1 mg resolution in bell and piston mass edit and view fields.
CHG: AutoGen (piston floating) routine sets piston to 1/2 of positive float deadband rather than to in deadband only.
FIX: Prevent deleting make up mass when editing mass sets.
FIX: Identification of PPC2+ in AutoGen (piston floating) routines to avoid hanging up in AutoGen initialization.

修订号: 
2.07h
  • 首页
  • 产品
    • 新产品
    • 电学计量校准
      • 标准器
      • 校准器
      • 高精度数字表
      • 电学校准软件
    • 射频校准
      • 射频参考标准
      • 射频校准配件
      • 射频校准软件
    • 数据采集和通用测试仪器
      • 台式万用表
      • 数据采集
      • 功能和波形发生器
      • 数据采集软件
    • 温度校准
      • 温度基标准
        • ITS-90 固定点容器
        • 标准铂电阻温度计 (SPRT)
        • 维修仪器
        • 液氮比较校准仪
        • 测温电桥
        • 标准电阻
      • 校准恒温槽
        • 袖珍型校准恒温槽
        • 标准型校准恒温槽
        • 特殊应用型恒温槽
        • 校准恒温槽配件
        • 校准恒温槽控制器
        • 校准恒温槽液
        • 自定义校准槽
      • 工业温度校准仪
        • 现场计量炉
        • 计量炉
        • 手持干井校准仪
        • 现场干式校准
        • 微型恒温槽
        • 红外校准器
        • 热电偶炉
        • 双插块干井
        • 零点干井
      • 二等标准温度计/温度传感器
        • 铂电阻温度计 (PRT)
        • 热敏电阻
        • 热电偶
      • 测温仪
      • 热工多产品校准器
      • 温度校准系统及软件
    • 湿度校准
      • 湿度发生器
      • 湿度数据记录仪和监测仪
    • 压力计量校准
      • 基准级活塞式压力计
        • NMI 活塞式压力计
        • 绝压活塞式压力计
        • 高压力气动活塞压力计
        • 液压活塞式压力计
        • 活塞式压力计附件
      • 数字压力控制器/校准器
        • 低压控制器/校准仪
        • 气动压力控制器/校准仪
        • 高压气动控制器/校准仪
        • 液压控制器/校准器
      • 压力检测器
        • 低压检测仪
        • 数字压力计
        • 参考压力检测仪
      • 活塞式压力计
        • 气压活塞压力计
        • 油活塞压力计
        • 水活塞压力计
        • 高压液压自动测试仪
        • 活塞压力计附件附件
      • 手动压力校准及精密压力测量
        • 压力校准仪
        • 气压控制
        • 液压比较器/泵
      • Handheld Pressure Calibrators
      • 大气数据校准
      • 环境检测仪
      • 手动调压装置及增压泵
      • 定制压力校准系统
      • 压力校准软件
    • 流量校准
      • 气体流量标准
      • 气体流量配件
      • GFS动态质量流量基准
      • 流量校准软件
    • 过程校准仪器
      • 过程温度校准器
        • 手持式温度校准器
        • 干体式温度校准器和微型恒温槽
        • 精密数字温度计
        • 温度探头
        • 红外校准器
        • 带数据记录功能的温湿度仪
      • 压力校准器
        • 数字压力校准器
        • 手持式压力校准器
        • 活塞式压力计
        • 精密数字压力计
        • 手泵
      • 热工多产品校准器
      • 便携式过程校准器
      • 过程校准软件
    • 校准软件
      • MET/CAL® 软件
      • MET/CAL® 金牌支持
      • 资产管理软件
      • 温度校准系统及软件
      • 压力校准软件
      • 流量校准软件
      • 通用校准软件
    • 售后服务
    • 所有校准仪器
  • 售前咨询
    • 联系方式
    • 索取报价
    • 请求演示
    • 产品咨询
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • 新闻及动态
    • 新闻发布
    • 促销活动
    • Metrology Salary Survey
  • 培训与活动
    • Conferences and Exhibitions
    • 培训课程
    • User Group Meetings
  • 资料下载
    • Education Hub
    • 关于校准
    • 应用文章
    • 产品资料
    • 用户手册
    • 视频、音频及虚拟演示
    • Blog
    • 产品样本(简体中文)
    • 常见问题(简体中文)
    • 应用文章(简体中文)
    • 用户手册(简体中文)
  • 售后服务
    • Service Request (RMA)
    • Service Plans
    • 知识库
    • 认证
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • 产品手册
    • 软件激活
    • 安全数据表 (SDS)
    • 安全通告
    • 软件下载
    • 软件激活
  • 关于我们
    • 联系我们
    • 访问我们
    • 加入我们
    • 福禄克计量校准部简介
      • DH Instruments 压力和流量校准
      • Pressurements 压力校准
      • Ruska 压力校准
    • 福禄克其他部门
    • 商业准则
    • 常见问题
  • QQ客服在线咨询
主页|文献|软件下载|固件|PG7000 Ver 2.07h Embedded Software

咨询福禄克计量校准产品的价格、销售渠道、技术等问题或申请产品的现场演示。

我们会尽快与您取得联系!

客服热线电话:400-8103435

©1995-2021 Fluke Corporation

Secondary menu

  • Disclaimer
  • 隐私声明
  • 网站管理员
  • 使用条款
  • Terms and Conditions of Sale